Attic sheathing Mold
Mold was caused by Bathroom fans venting into attic space

Attic sheathing boards
considerable amount of mold from improper ventilation

Mold in attic on sheathing
Mold caused from humidity and incorrect ventilation

Disconnected duct
Bathroom fan blowing warm air into the attic space

Disconnected Duct
No connection, blowing warm air into attic space

Cleaned sheathing in attic
Remediated mold and air sealed top plate

Bath fan
duct connection from bathroom below

Air Seal
sealed all accessible penetrations with expanding polyurethane

Wye Connector
connected two fan ducts with a wye connector to exit out the gable wall

New baffles
Durovent baffles installed into the eave after clearing insulation and debris

Blow in TruSoft Cellulose
Insulation blown in to R60 approximately 17"

TruSoft Cellulose
Insulation blown for a R60 approximately 17"